FIELD OPERATION GUIDE
YSI 610 DISPLAY/LOGGER
CONNECTING TO A SONDE
Since YSI 6-Series sondes do not have displays or con-
trols, users must communicate to them with a PC or ter-
minal and emulation device. The figure below is a dia-
gram of the YSI 610 connected to any 6-series sonde.
68
20
610-DM
Envir onm ent al
Monitoring
Syst em s
YSI
RUN
TMP 20.54
CND 0.687
DO% 97.5
DOc 38.0
pH 8.32
NO3 2.35
SpC 0.750
SAL 1.42
DO 8.56
DEP 10.12
ORP 90.2
TRB 2.3
610 Handheld Display
The 6-Series Sonde.
Two slide plug cable adapters are available for the com-
munications plug. One is for communication with a PC
and terminates in a 9-pin miniature sub-D connector.
When communicating with a PC, be sure to use a null
modem cable. The other adapter is for use with a sonde
and terminates in an 8 pin, military style connector. Plug
the MS-8 end of the cable into the sonde and the other
end into the YSI 610.
610-DM
Environmental
Monitoring
Systems
YSI
AC Adaptor for 120 VAC
DB-9 Pigtail
MS-8 Pigtail
Power Jack Module
Null Modem Cable
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - FIELD OPERATION GUIDE

1FIELD OPERATION GUIDEYSI 610 DISPLAY/LOGGERCONNECTING TO A SONDESince YSI 6-Series sondes do not have displays or con-trols, users must communicate t

Página 2 - SAMPLING APPLICATIONS

2SAMPLING APPLICATIONSSampling applications refer to readings that are takenwhile the user is present and controlling the collection ofdata. In sampli

Página 3 - SITELIST

3USING THE SITE LIST WITH THE MARKED FILEThe Site List is accessed through the Setup 610 menu.When using the Mark feature, there is only one filename,

Página 4 - LOGGING WITH THE 610-DM

4USING THE SITE LIST FOR CAPTURE, ADD ANDLOG FILESFrom Main menu scroll to Setup 610, press Enter, thenscroll to Setup Site List. To modify an existin

Página 5

5of 4 sec). On all other sondes, the DO warm-up shouldbe set to 120 seconds. Be sure to recalibrate DO anytimeyou change the DO warm-up.To begin log

Página 6 - 610-DM TO A PC

6From the Main menu go to the Communications menuand select Kermit 610 < Sonde. When you see the direc-tory displayed, select the desired file and

Página 7 - You will need

7Upload 610 Data Files to Lab ComputerYou will need...!610-DM!6099 DB-9 Adapter!Null Modem Cable!DB-9 to DB-25 Adapter maybe needed at Com Port610-DM

Página 8

8YSI Incorporated1725 Brannum LaneYellow Springs, Ohio 45387 USA(800) 897 4151  (937) 767 7241Fax: (937) 767 9353http://www.ysi.come-mail: [email protected]

Comentários a estes Manuais

Sem comentários